Resetting project
From Unofficial BOINC Wiki
Contents |
[edit] General
Message Type: Information Message
This message means that the BOINC Client Software has been directed by the Participant to "Reset" the Project by the Participant selected commands in the Projects Tab's BOINC Manager Tasks:
- "Detach", or
- "Reset"
With a Project name selected in the Project List shown in the Projects Tab.
Selection of either of these two options will cause the BOINC Client Software to perform a Project "Reset".
Note: When a Project is "Reset", all Work Units are terminated and work completed but not "reported" will also be abandoned. This means that you will lose any possible Credit that you may be eligible for. So, before doing a Project "Reset", do a Project "Update" to report all work not yet reported.
[edit] Example Log(s)
[edit] Reset
In this example we do a "Project "Reset" and then follow it with a Project "Update".
6/5/2005 9:36:04 AM|climateprediction.net|Resetting project
-+-+/\/\/\/\/\ Log Break /\/\/\/\/\-+-+-
6/5/2005 9:36:27 AM|climateprediction.net|Sending scheduler request to
http://climateapps2.oucs.ox.ac.uk/cpdnboinc_cgi/cgi
6/5/2005 9:36:28 AM|climateprediction.net|Scheduler request to
http://climateapps2.oucs.ox.ac.uk/cpdnboinc_cgi/cgi
succeeded
[edit] Line-By-Line Explanation
- Resetting project
- This message indicates that the BOINC Client Software is performing the Project "Reset".
- In this log we are also showing a request to the Project's Scheduler.
- And in this case we had success!
[edit] Reset & Detach
6/4/2005 6:32:15 PM|Pirates@Home|Resetting project 6/4/2005 6:32:15 PM|Pirates@Home|Detaching from project
[edit] Line-By-Line Explanation
- Resetting project
- This message indicates that the BOINC Client Software is performing the Project "Reset".
- The connection between the Participant's Computer and the BOINC Powered Project is severed.
[edit] Can't Resolve Hostname - Host Not Found
- Note:
- In this log example, I tried to attach to a Project with a "bogus" URL, just to make this set of messages ... but this is still the error you would get regardless of the reason that the URL is bad.
2005-06-03 02:51:27 [ ] Can't resolve hostname [climateprediction.net1]
host not found
2005-06-03 02:51:27 [http://climateprediction.net1/] Couldn't read master page for
http://climateprediction.net1/:
error -113
2005-06-03 02:51:27 [http://climateprediction.net1/] Detaching from project - check for URL error
BOINC couldn't get main page for
http://climateprediction.net1/.
Please check the URL and try again.
2005-06-03 02:51:27 [http://climateprediction.net1/] Resetting project
2005-06-03 02:51:27 [http://climateprediction.net1/] Detaching from project
Line-By-Line Explanation
- The "host-name" used is in error, usually caused by incorrect typing or copying of the URL when "Attaching" the BOINC Client Software to a BOINC Powered Project.
- Because the Project's Master URL was wrong, the Project's Master Page could not be read.
- Please check the URL and try again.
- The BOINC Client Software is offering a hint as to the problem.
- Resetting project
- Detaching from project
- And, because of that, we have to "Detach" From The Project, which includes a Project "Reset".
[edit] Other Related Messages
- When the "Attach" process fails, a Project "Reset" and "Detach" are performed.
RSS Feeds