[edit] General

This is the "Name" of the Work Unit. The Work Unit has, in fact, two items that will uniquely identify it. One is the human readable "Name" and the other is the Work Unit ID. The Work Unit ID is a number which is used by the database to track the Work Unit (for database freaks, the Primary Key value). This second, usually hidden value, is the one that is a positive integer that is used in the links connecting pages like the "Result" Page to the "Work Unit" Page.

The one we are concerned about here is a descriptive name that uses a Project specific scheme to create uniquely named object of work. For example, the SETI@Home Project identifies the tape from which this Work Unit has been extracted, along with a bunch of other information about the source of the Work Unit.

Other BOINC Powered Projects will be doing the same type of thing, but in the context of their Project. There is one constant across all Projects the last number in the Work Unit Name is the Result Identifier. For the most part this is a lot of "who cares?" other than we know that the Work Unit has a unique identifier.

The way that the Work Units are identified should be described on that Project's Web Site (if you really care that much). The identification data may be a simple, but long identifier, or may have within its seemingly random collection of numbers, letters, and punctuation encoded information that can be decoded if you send in enough box-tops and get the Genuine Captain Paul Marvell's Magic Secret Decoder Ring (the ring itself is free, but the shipping and handling is a low, low $56.95 U.S.; don't wait, rush down to the post office while supplies last …).

A Result Name is simply a modification of the Work Unit Name by adding an identifier. This identification number, as a suffix to the Work Unit Name, provides a means of establishing a unique Result identifier. So, when the Work Unit is split into Results to be sent out to the Participant's Computers, a Result Identifier is appended to the Work Unit Name. The format of this identifier is "_#". An underscore ("_") separates the Result Identifier from the Work Unit Name. The "#" is replaced with the sequence number beginning with zero (0) and continuing upwards in increasing value.

This value may, if the Project requires, be more than a single digit in length.

[edit] Example: BURP

In the BURP Project, for example, the Work Unit Name breaks down as follows:

Work Unit Name: 137in0.zip__ses0000000137_frm0000000282_prt00003.wu
Name Part Description
137in0.zip The session number.
ses0000000137 The session number again.
frm0000000282 The frame number.
prt00003 The part number.
wu This is a Work Unit.


Note:
When the Work Unit is split into Results and sent out to Hosts for processing a Result Identifier is appended to the Work Unit Name. The format is "_#". The underscore ("_") separates the Result Identifier from the Work Unit Name. The "#" is replaced with the sequence number beginning with zero (0).


[edit] Example: LHC@Home

In the LHC@Home Project, for example, the Work Unit Name breaks down as follows:

Work Unit Name: wjun4B_v6s4hhpac_mqx__9__64.2914_59.3077__6_8__6__10_1_sixvf_boinc12302
Name Part Description
wjun4B A workspace directory name
v6s4hhpac_mqx The study name where:
v6s4 LHC Version 6 Subversion 4
hhpac_mqx Just a name for the particular physics case
9 The current seed number (typically between 1 and 60) representing a set of magnet errors
64.2914_59.3077 The tunes x and y (the current topic of investigation)
6_8 The initial amplitude range of the tracked particles
6 The order of the the number of turns 1000000
10 The initial angle in phase space (between 0 and 90 degrees)
1_sixvf_boinc12302 Identification string for the BOINC System


Note:
When the Work Unit is split into Results and sent out to Hosts for processing a Result Identifier is appended to the Work Unit Name. The format is "_#". The underscore ("_") separates the Result Identifier from the Work Unit Name. The "#" is replaced with the sequence number beginning with zero (0).

[edit] Example: Rosetta@Home

In the Rosetta@Home Project, for example, the Work Unit Name breaks down as follows:

Work Unit Name: 1btn__abrelax_32948
Name Part Description
1btn The first four characters represent the pdbid of the protein being tested.

Where the pdbid is the uniquie identifier given to each structure in the Protein Data Bank. A pdbid is represented by a 4 character alphanumeric identifier, assigned upon its deposition. For example, 4hhb and 9ins are identification codes for PDB entries for hemoglobin and insulin, respectively. Many of the PDB Web site pages, including the PDB home page, allow you to enter a PDB ID and retrieve information for the corresponding structure.

More details

abrelax Signifies that the Work Unit is going to be doing low resolution ab "initio prediction" followed by high resolution full-atom relax.
32948 The Work Unit specific identifier.


Note:
The names are fairly arbitrary and will change with different experiments.
Note:
When the Work Unit is split into Results and sent out to Hosts for processing a Result Identifier is appended to the Work Unit Name. The format is "_#". The underscore ("_") separates the Result Identifier from the Work Unit Name. The "#" is replaced with the sequence number beginning with zero (0).

[edit] Example: SETI@Home

In the SETI@Home Project, for example, the Work Unit Name breaks down as follows:

Work Unit Name: 08au03ab.28481.2178.117304.159
Name
Part
Description
08au03ab This indicates the date the data was recorded and the tape number where this Work Unit was recorded. In this case the signal was recorded on the 8th of August 2003 and it was recorded on tape "ab" which is the second tape of the day.

This breaks down as:

  • dd - day number
  • mm - month abbreviation
ja January
fe February
mr March
ap April
my May
 ?? June
jl July
au August
se September
oc October
no November
dc December
  • yy - year number
  • tt - Tape "number", The first tape is identified as "aa"; the second as "ab"; the third as "ac"; and so on …
28481 This is the "process ID" (or process number) of the "Splitter" program that is running on the server that is writing out the file. This allows them to trace back if there is a failure with a particular batch of Work Units.
2178 The tape's current record number. This identifies the location along the length of the data tape which is where this Work Unit's data was recorded. I'm not sure what the record size is in this case, but basically how far along into the tape we are - probably the same as the "block" number on the tape.
117304 The byte offset from the start of the record number where the Work Unit's data actually starts (in any case, it is another datum about Work Unit's position on the tape).
159 Spectrum Identification Value:
SETI@Home looks at 2.5 MHz of data, centered at 1420 MHz. This is still too broad a spectrum to send to a Participant for analysis, so the project will break this spectrum space up into 256 pieces, each 10 KHz wide (actually a little less than 10 KHz)
These pieces are numbered 0 to 255, so a piece with the number 159 is piece #160.


Note:
When the Work Unit is split into Results and sent out to Hosts for processing a Result Identifier is appended to the Work Unit Name. The format is "_#". The underscore ("_") separates the Result Identifier from the Work Unit Name. The "#" is replaced with the sequence number beginning with zero (0).